Hi Patrick,
> However the source in s6-svscan:107
>
> case SIGTERM : cont = 0 ; wantkill = 1 ; killmode = KILLMODE_ACTIVE | KILLMODE_SERVICES ; break ;
>
> Is different from s6-svscan:130
>
> case 't' : cont = 0 ; killmode = KILLMODE_ACTIVE | KILLMODE_SERVICES ; return ;
Good catch. That's what happens when you duplicate code...
I'll release a patched version soon.
Thanks for the bug-report!
--
Laurent